Prioritize the fan cable check, the extinguisher’s placement and readiness, and the damaged wall near electrical outlets. Then complete the functional repairs, cleanup and signage work documented below.
Prepared 14 October 202613 supplied photographsCampus and inspection date: to confirm
Priorities for the next walkthrough
These are proposed work-sequencing priorities. They are not confirmed hazard levels or compliance ratings. Owners and target dates remain unassigned.
3
Check first
P03 fan cable before cleaning; P12 extinguisher position and readiness; P13 wall condition around outlets before cleanup or reuse decisions.
5
Repair and restore
P04 door handle; P06 sink-cabinet edging; P07 overfilled cupboard and floor; P09 chair; P10 detached door panel or edging.
Fan area: the photo shows a hanging cable and an apparent taped connection. Arrange a qualified electrician check before cleaning; do not touch or spray the connection.
Extinguisher: agree a dedicated, accessible position with the responsible fire-safety person or service provider. Its worn label means type, suitability and service status must be verified onsite.
Corner outlets: peeling or blistered wall finish is visible. Moisture is one possible explanation, not a confirmed diagnosis. If damp is present, avoid using the affected outlets or wet-cleaning around them until appropriately checked.
Nothing in this report records a completed repair, tested electrical installation, certified extinguisher, active leak, mold diagnosis or overall compliance result. Location descriptions identify what is shown; only the first floor bathroom was explicitly named.
Action register
Use the photo reference to review the evidence and the closure check. Confirm scope onsite, assign an owner and agree a due date before tracking completion.
Clean and refresh the window wall to match the kitchen finish.
To assign
To agree
Open
Photo findings and recommendations
Each record separates the user’s request, visible evidence, proposed action and onsite checks. Select any photo to inspect it at a larger size.
Photo P01Planned improvement
Reinstate the door sign
Brown framed glass door; exact room not confirmed
P01 · Supplied photograph. Select to enlarge.
User request or note
The sign needs to be placed here again.
Visible in the photograph
Brown framed door with frosted or opaque film on glass.
The central film area is worn or partly removed, with visible residue; no legible sign is visible in the photographed area.
Recommended action
Confirm the intended sign wording and purpose, then reinstate a durable, readable sign at the intended location.
Clean adhesive residue and repair or replace the affected film as appropriate.
Confirm onsite
Confirm room, sign type, wording and position.
Check whether the missing sign has a safety or access function; reprioritize if it does.
Confirm the film condition and suitable cleaning method.
Close when
After photo showing the reinstated readable sign and finished glass surface.
Owner: to assignDue date: to agreeStatus: open
Photo P02Planned improvement
Make the bathroom cleaning record easy to read
First floor bathroom, as identified by user
P02 · Supplied photograph. Select to enlarge.
User request or note
Photo identified as the first floor bathroom.
Visible in the photograph
A sheet headed WASHROOM CLEANING is mounted on the wall.
Loose or folded paper obscures part of the displayed record.
The surrounding wall has visible scuffing, adhesive traces and areas of finish loss.
Recommended action
Secure the current cleaning sheet flat in a suitable holder so entries can be read and updated.
Clean the surrounding wall and restore damaged finish where needed.
Confirm onsite
Check the actual current dates, completed entries and cleaning routine onsite; these are not reliably readable in the photo.
Check the bathroom itself separately; this photograph shows the record display rather than the whole room.
Close when
After photo of a flat, legible current log and restored surrounding surface.
Owner: to assignDue date: to agreeStatus: open
Photo P03Check first
Check the fan cable before cleaning
Exhaust fan and surrounding panel; exact room not confirmed
P03 · Supplied photograph. Select to enlarge.
User request or note
The area needs cleaning.
Visible in the photograph
Dust or surface deposits are visible on the fan housing and dark surrounding panel.
A cable hangs below the fan and an apparent taped connection is visible near the lower left.
Not established by the photo. The visible cable routing and apparent taped connection need onsite assessment; electrical safety cannot be determined from a photograph.
Recommended action
Have a qualified electrician inspect the cable routing and apparent connection and make any necessary repair or enclosure before the area is cleaned.
Do not touch or spray the visible connection. Clean the fan and surround only after safe isolation and clearance by the appropriate person, following the equipment instructions.
Confirm onsite
Confirm circuit isolation and electrical condition onsite.
Check secure mounting and fan operation after any repair and cleaning.
Close when
Electrician confirmation of required corrective work and after photo of the safely finished, cleaned area.
Owner: to assignDue date: to agreeStatus: open
Photo P04Repair and restore
Restore the missing door handle
Brown door; exact room not confirmed
P04 · Supplied photograph. Select to enlarge.
User request or note
The handle is missing.
Visible in the photograph
Mounting holes and the outline of former hardware are visible on the brown door.
No handle is present in the photographed mounting area.
Recommended action
Fit suitable replacement door hardware and make good the mounting surface.
Test opening, closing and latching from both sides where applicable.
Confirm onsite
Identify the room and the door's function.
Confirm no one can become trapped and that intended access is maintained; if this is an exit or privacy-critical door, escalate repair priority.
Confirm the latch, lock and door condition before selecting replacement hardware.
Close when
After photo of fitted hardware and an onsite function check.
Owner: to assignDue date: to agreeStatus: open
Photo P05Planned improvement
Replace unreadable cabinet labels
Dark cabinet or drawer fronts; exact room not confirmed
P05 · Supplied photograph. Select to enlarge.
User request or note
The nameplate is not visible or readable.
Visible in the photograph
Two labels are visible on dark fronts; one is worn or faded and the other is partly missing or unreadable.
White containers with dark caps stand at floor level beside the cabinet; their contents cannot be established from the image.
Recommended action
Confirm the contents or purpose of each compartment and apply durable, readable labels.
Check the nearby containers' identities and storage arrangements onsite without assuming their contents.
Confirm onsite
Verify the exact label wording against actual contents.
Check whether identification relates to allergens, chemicals or another controlled use; escalate as needed based on verified contents.
Close when
After photo showing correctly matched, readable labels.
Owner: to assignDue date: to agreeStatus: open
Photo P06Repair and restore
Repair damaged sink-cabinet edging
Sink-side cabinet edge; exact room not confirmed
P06 · Supplied photograph. Select to enlarge.
User request or note
No accompanying user note. The observations below are based on the photograph.
Visible in the photograph
Water droplets and a wet area are visible on the sink surround.
The upper cabinet trim is bowed or peeling away, exposing rough substrate beneath it.
Not established by the photo. Moisture exposure may be contributing to the damaged edge, but the cause, depth of damage, any active leak and any microbial growth cannot be determined from the photo.
Recommended action
Dry the area and inspect the sink joint, nearby plumbing and cabinet material to identify the source of wetting.
Correct any verified source, then replace or repair affected edging or substrate to provide a sound, cleanable finish.
Confirm onsite
Check moisture, plumbing and sink-seal condition.
Assess whether the underlying board remains sound and whether any trim is sharp or loose.
Confirm there is no continuing wetting after repair.
Close when
After photo of a sound finished edge and confirmation that the source of wetting has been checked.
Owner: to assignDue date: to agreeStatus: open
Photo P07Repair and restore
Clear and reset the under-sink cupboard
Cupboard beneath double sink; exact room not confirmed
P07 · Supplied photograph. Select to enlarge.
User request or note
The cupboard is overloaded with items and will not close.
Visible in the photograph
Cupboard doors below the double sink stand partly open.
The cupboard contents are not visible well enough to confirm the reason the doors are open.
The floor finish immediately in front shows worn or missing patches.
Not established by the photo. The user reports overloading; hinge condition, alignment and other obstructions still need checking onsite.
Recommended action
Remove excess items and reorganize storage so doors close freely and plumbing remains accessible.
Check hinges and alignment after clearing the cupboard.
Inspect and repair the damaged floor finish as needed to leave a sound, cleanable surface.
Confirm onsite
Inspect actual contents, storage suitability and the cause of obstruction.
Check for any wetting under the sink and any loose floor edges.
Confirm the closed doors leave the walking route clear.
Close when
After photos of organized contents, closed doors and repaired floor finish, plus a door function check.
Owner: to assignDue date: to agreeStatus: open
Photo P08Planned improvement
Reinstate signage at the second door location
Wall beside and above a grey framed glass door with a folding metal gate; exact room not confirmed
P08 · Supplied photograph. Select to enlarge.
User request or note
Signage needs to be put back at this location.
Visible in the photograph
Several rectangular patches and mounting remnants are visible on the wall beside and above the door.
No legible sign is visible at those patches.
The glass film shows a large irregular worn or removed area.
Recommended action
Confirm each sign and its intended position, then reinstate durable, legible signage.
Remove redundant mounting residue and make good the wall and damaged glass film as appropriate.
Confirm onsite
Confirm which wall positions the user intends and the required wording for each sign.
Confirm the room and whether any of the signs has a safety, access or directional function; reprioritize accordingly.
Close when
After photo showing the restored signage in its intended positions and finished mounting surfaces.
Owner: to assignDue date: to agreeStatus: open
Photo P09Repair and restore
Replace the damaged chair and inspect the others
Chair beside a work counter; exact room not confirmed
P09 · Supplied photograph. Select to enlarge.
User request or note
Chairs are to be replaced.
Visible in the photograph
The main chair backrest has extensive torn or peeling black covering.
Inner material and a wood-like strip are exposed along the damaged backrest.
Not established by the photo. The photograph does not establish frame strength, joint stability or the total number of affected chairs.
Recommended action
Replace the visibly damaged chair as requested.
Inspect the other chairs and confirm the replacement quantity before procurement.
Have any chair with loose components, sharp edges or instability taken out of service pending repair or replacement.
Confirm onsite
Check the frame, backrest fixings, folding mechanism, feet and stability.
Confirm how many chairs are affected and the required replacement type.
Close when
Replacement count confirmed onsite and after photo of sound chairs with intact, cleanable finishes.
Owner: to assignDue date: to agreeStatus: open
Photo P10Repair and restore
Refit or replace detached cabinet edging
Cabinet beneath a stainless steel worktop; exact room not confirmed
P10 · Supplied photograph. Select to enlarge.
User request or note
The side panel or edging of a door is opening up and needs to be glued or repaired.
Visible in the photograph
A hand holds the open cabinet front near its upper edge.
A narrow dark edge strip is detached or peeling away, exposing the wood-like core beneath.
Not established by the photo. The full extent of the panel or hinge damage is not shown.
Recommended action
Assess the panel and substrate, then securely re-bond sound edging with a suitable method or replace damaged parts. Do not rely on glue alone if the material is deteriorated.
Check the whole door, hinges and adjoining panels before completing the repair.
Confirm onsite
Check whether the detached part is edge banding or a larger side panel and whether its substrate is sound.
Check for sharp or loose edges, panel damage and free door movement.
Close when
After photo of secure, smooth edging and confirmation that the cabinet door operates freely.
Owner: to assignDue date: to agreeStatus: open
Photo P11Planned improvement
Refresh the wall and window area
Arched barred window; exact room not confirmed
P11 · Supplied photograph. Select to enlarge.
User request or note
The user wants this wall and window area improved to match the appearance of the overall kitchen.
Visible in the photograph
An arched window with translucent panes or film is visible behind horizontal metal bars.
Dark deposits or worn finish are visible around frame edges and the sill.
Irregular fine lines are visible in the upper translucent areas; the photo does not resolve whether they are on film, surface finish or glass.
Scuffs and fine marks are visible on the surrounding pale wall.
Not established by the photo. The pane and surface condition needs closer onsite examination; cracked glass is not confirmed.
Recommended action
Clean the wall, sill, frame and bars, then make good damaged finish.
Agree a wall and window finish consistent with the kitchen before repainting or replacing film.
Check pane and seal condition before choosing a cleaning or repair method.
Confirm onsite
Confirm the desired appearance, finish and room context.
Check whether any pane is cracked, loose or poorly secured before cleaning.
Check seals, latches and opening function where applicable.
Close when
After photo of the restored window and confirmation that pane condition and fixings were checked.
Owner: to assignDue date: to agreeStatus: open
Photo P12Check first
Give the extinguisher a dedicated position
Fire extinguisher standing by a wall below a window; exact room not confirmed
P12 · Supplied photograph. Select to enlarge.
User request or note
The extinguisher needs a dedicated place.
Visible in the photograph
A red portable fire extinguisher stands on the floor by the wall.
Its main body label is substantially worn or partly removed.
The photo does not provide a readable service record, rating or operating instructions.
Not established by the photo. Type, suitability, inspection date and operational readiness cannot be established from this image; expiry or failure is not confirmed.
Recommended action
Have the responsible fire-safety person or competent service provider choose a stable, clearly identified and unobstructed designated position with an appropriate mount or stand.
At the same visit, verify the extinguisher type, condition, service status and suitability, and restore readable identification and instructions.
Confirm onsite
Check service documentation, seal or pin, hose or nozzle, body condition and pressure indication if the model has one.
Confirm the appropriate number, type and placement of extinguishers onsite; the photo shows only this unit.
Close when
Service or inspection confirmation and after photo showing readable identification and the verified designated position.
Owner: to assignDue date: to agreeStatus: open
Photo P13Check first
Clean the corner and decide its use
Lower-wall corner with multiple electrical outlets beside a stainless steel fixture; exact room not confirmed
P13 · Supplied photograph. Select to enlarge.
User request or note
The corner is dirty and should be cleaned; the user wants to decide what to put there afterward.
Visible in the photograph
Lower-wall paint or finish is blistered, uneven and peeling around several low-level outlet plates.
Discoloration is visible near the wall base and corner.
Local floor-finish loss and small loose material are visible nearby.
Not established by the photo. Moisture may be involved, but active damp, the source, hidden damage and electrical condition cannot be determined from the photograph.
Recommended action
Check the damaged lower wall and any damp before cleaning near the outlets; arrange a qualified electrical check if damp or outlet damage is found.
Clean the corner with a method appropriate to the surfaces, and correct any verified cause before repairing damaged finishes.
Decide what belongs there after cleanup and access checks. Keep outlet access and any required service or walking clearance available; no new furnishing or storage has been selected.
Confirm onsite
Check whether the wall is currently damp and investigate the source if it is.
Check outlet security and electrical condition through a qualified person.
Check adjacent floor and wall materials for loose sections and repair extent.
Confirm usable dimensions and whether the corner must remain clear for equipment, service or access before choosing storage or decor.
Close when
Confirmation of moisture and electrical checks as applicable, correction of any verified cause and after photos of sound finishes.
Owner: to assignDue date: to agreeStatus: open
Blank onsite inspection checklist
A companion verification tool for a teaching kitchen. None of the boxes below has been assessed from the photos. Blank means not inspected.
Before use: the campus lead should confirm the applicable licence category, local requirements, equipment instructions and product-specific procedures. This checklist supports operations and does not certify compliance.
How to record: P = pass against actual evidence; F = fail, including a required control that cannot be verified; N/A = genuinely not applicable with a reason recorded. Add an evidence or action reference for each finding. Record failures and assign their owners and due dates.
Safety gate: if a gate fails, stop the affected activity, follow the site’s emergency or isolation procedure and inform the duty lead. Resume only after the condition is controlled and an authorised lead verifies it. Never operate a switch near a suspected gas leak. Do not dismantle equipment or test hazardous systems during this walkthrough.
Suggested operating cadence from the companion checklist: opening and closing checks each class; a full inspection monthly and after a serious incident, major change or repeat failure. The campus lead should approve the actual cadence.
Campus and full address: ______________________________________________
Kitchen or room: ___________________ Inspection date and time: ___________________
Inspector and role: ___________________ Duty lead or chef: ___________________
Class or batch: ___________________ Students / instructors present: ______ / ______
Safety gate
ID
Onsite check
P
F
N/A
Ref
G1
No gas smell, uncontrolled flame, smoke, sparking, exposed live parts or unsafe water near electrics.
□
□
□
G2
Exits and evacuation routes are usable; required fire protection is accessible and serviceable.
□
□
□
G3
Safe water and a usable, supplied handwash point are available for the activity.
□
□
□
G4
No sewage overflow, serious pest contamination, chemical spill or foreign-body incident affecting food.
□
□
□
G5
High-risk food has a verified safe time and temperature history; suspect food is held from use.
□
□
□
G6
No symptomatic food handler, uncontrolled allergen mix-up, or unsafe exposed wound handling food.
□
□
□
G7
Guards and required extraction work; unsafe machines, ovens and hot-work setups are isolated and labelled out of service.
□
□
□
G8
Competent supervision, task space, first-aid cover and a reliable way to summon help are available for the planned activity.
□
□
□
Evidence and readings: __________________________________________________________________
People water and hygiene
ID
Onsite check
P
F
N/A
Ref
001
Food handlers and instructors report vomiting, diarrhoea, fever, infected wounds and other relevant illness before handling food.
□
□
□
002
Unwell handlers are removed from food-handling duties under the campus illness procedure; return-to-work clearance is recorded.
□
□
□
003
Handwash points are accessible, working and separate from food washing; soap and hygienic hand-drying supplies are stocked.
□
□
□
004
Handlers wash hands before work and after toilet use, waste, raw eggs, phones, cleaning and other contamination.
□
□
□
005
Gloves, where used, are changed between tasks and never substitute for handwashing; ready-to-eat contact is controlled.
□
□
□
006
Clean protective clothing, hair restraints and suitable closed non-slip footwear are worn; loose sleeves and scarves are secured.
□
□
□
007
Nails are short and clean; jewellery, watches, artificial nails and loose personal items cannot contaminate food or catch machinery.
□
□
□
008
Cuts are covered with suitable waterproof dressings; extra protection is used where needed and dressings are accounted for.
□
□
□
009
Eating, chewing, smoking and personal drinks are kept away from preparation areas; tasting uses clean single-use or washed utensils.
□
□
□
010
Toilets and changing areas are clean and supplied; toilet access does not expose food to contamination.
□
□
□
011
Personal bags, phones, coats and outdoor shoes are stored away from ingredients, worktops and clean equipment.
□
□
□
012
Food-contact water and ice are potable; source-specific testing requirements and current reports or supply evidence are verified.
□
□
□
013
Water tanks, filters and treatment units have current cleaning, servicing and replacement records; overdue actions are addressed.
□
□
□
014
Food-contact ice is made, stored and scooped hygienically; scoops have a protected storage point and hands do not contact ice.
□
□
□
015
Water pressure and drainage are adequate; leaks, backflow risks and cross-connections with non-potable water are controlled.
□
□
□
016
First-aid supplies and trained cover are ready; emergency contacts, exact site address and incident-reporting routes are known.
□
□
□
Evidence and readings: __________________________________________________________________
Deliveries storage and cold chain
ID
Onsite check
P
F
N/A
Ref
017
Suppliers are approved; purchase and delivery records identify source, batch and any applicable licence or registration.
□
□
□
018
Deliveries are inspected for damaged packs, pests, spoilage, contamination and expiry; rejected goods are segregated and recorded.
□
□
□
019
Chilled deliveries meet the approved specification and move promptly into storage; frozen deliveries show no thawing or refreezing.
□
□
□
020
Eggs are sound and traceable; cracked or leaking eggs are rejected, and cartons or trays cannot contaminate ready-to-eat work.
□
□
□
021
Milk, cream, butter, cheese and pasteurised egg products are within date and stored according to the label after opening.
□
□
□
022
Cold food is held at 5°C or below; animal-origin foods at 4°C or below where the cited FSSAI catering criteria apply.
□
□
□
023
Frozen food is held at −18°C or below; doors, seals and defrost systems work and excessive ice does not restrict storage.
□
□
□
024
Chiller and freezer readings are logged at the campus-defined frequency; excursions trigger a documented food-safety decision.
□
□
□
025
Food probes are suitable, clean and checked for accuracy against a documented method; air displays are not the only evidence.
□
□
□
026
Cold stores allow airflow and separate raw ingredients from ready-to-eat food; raw eggs cannot drip onto finished products.
□
□
□
027
Every opened or prepared item has identity, preparation/opening date, use-by time or date and any storage instruction.
□
□
□
028
First-expiry-first-out stock rotation is followed; expired, unlabelled and suspect items are held from use pending a safe decision.
□
□
□
029
Flour, sugar, nuts and chocolate are dry, covered, pest-free and kept off the floor with access for cleaning and inspection.
□
□
□
030
Storage and packaging are intact and food-grade; decanted containers retain identity, allergen and batch traceability.
□
□
□
031
Cleaning chemicals, pest products and maintenance materials are labelled and secured away from food and packaging.
□
□
□
032
Power-loss or chiller-failure plans identify an alternate cold store, food-hold procedure and responsible decision-maker.
□
□
□
Evidence and readings: __________________________________________________________________
Pastry production and allergen controls
ID
Onsite check
P
F
N/A
Ref
033
Current recipes state ingredient weights, process steps, yield, allergen content and food-safety controls for the product.
□
□
□
034
Raw eggs and raw flour are kept away from ready-to-eat fillings and decorations; raw batter or dough is not tasted.
□
□
□
035
Pasteurised egg is used for uncooked or lightly cooked preparations unless an approved validated safety process is followed.
□
□
□
036
Custards, pastry cream, dairy fillings and other high-risk products follow a validated cooking process with required records.
□
□
□
037
Where applicable, cooked high-risk food cools from 60°C to 21°C within 2 hours, then to 5°C within a further 2 hours.
□
□
□
038
Cooling uses suitable portions, shallow containers or rapid-cooling equipment; time and product-core readings verify the process.
□
□
□
039
High-risk portioning is refrigerated or the product returns to refrigeration within 30 minutes, per the cited catering criterion.
□
□
□
040
Cream piping bags, nozzles, whipped cream and filled pastries are protected and kept within their approved holding limits.
□
□
□
041
Food thaws by an approved controlled method; thawed portions are dated and their safe use window is defined.
□
□
□
042
Where reheating applies, food reaches a core temperature of 75°C for at least 2 minutes; the relevant record is retained.
□
□
□
043
Prepared products have an approved shelf life and storage condition; time left on benches, display or in transport is controlled.
□
□
□
044
An up-to-date recipe allergen matrix covers ingredients and substitutions, including compound chocolate, decorations and premixes.
□
□
□
045
Milk, egg, gluten cereals, nuts, peanuts, soy, sulphites and other relevant allergens are identified; supplier label changes are checked.
□
□
□
046
Allergens have marked, segregated storage and tools; dust is contained and shared equipment is effectively cleaned between uses.
□
□
□
047
Special-diet requests are checked; eggless is not treated as allergen-free and no unsupported allergen-free promises are made.
□
□
□
048
Finished products have allergen and storage/use information; any prepacked sale meets applicable retail labelling requirements.
□
□
□
Evidence and readings: __________________________________________________________________
Cleaning pests and premises
ID
Onsite check
P
F
N/A
Ref
049
A written cleaning schedule names each area or item, method, chemical, frequency, responsible person and verification step.
□
□
□
050
Food-contact worktops, utensils and equipment are visibly clean before use and cleaned between incompatible tasks.
□
□
□
051
Cleaning precedes sanitising; food-safe chemicals are used at the label dilution and contact time, with required rinsing.
□
□
□
052
Sanitiser concentration is checked by an appropriate method where needed; bottles are labelled and never reused food containers.
□
□
□
053
Mixer bowls, attachments, scrapers, seals and removable guards are cleaned without leaving trapped dough or cream.
□
□
□
054
Piping tips, sieves, cloths, brushes and small tools are cleaned, dried and stored so hidden residue cannot build up.
□
□
□
055
Dishwashing separates dirty and clean items; the validated machine cycle or manual wash-and-sanitise method is followed.
□
□
□
056
Clean equipment air-dries and is protected; dirty towels do not recontaminate utensils, hands or worktops.
□
□
□
057
Cleaning tools are separated by use, kept serviceable and stored away from food; toilet tools never enter food areas.
□
□
□
058
Floors, walls, ceilings and work surfaces are sound and cleanable; broken tiles, flaking paint and mould are addressed.
□
□
□
059
Drains flow freely and are clean; grease traps are maintained and cleaning does not splash exposed food or clean equipment.
□
□
□
060
Waste bins are suitable, lined where needed, covered when appropriate and emptied before overflow; external waste is controlled.
□
□
□
061
Doors, screens and service penetrations deter pests; no fresh droppings, gnaw marks, insects or nesting are present.
□
□
□
062
A pest-control plan, visit reports and corrective actions are current; devices and treatments cannot contaminate food.
□
□
□
063
Required extraction operates during gas use; hoods and filters are clean and condensation cannot drip onto food.
□
□
□
064
Lighting is adequate and protected where breakage could contaminate food; glass and brittle-plastic breakage controls are known.
□
□
□
Evidence and readings: __________________________________________________________________
Equipment gas electrical and fire safety
ID
Onsite check
P
F
N/A
Ref
065
Equipment is stable, suitable for the task and used within the manufacturer’s capacity; safe instructions are available.
□
□
□
066
Machine guards and restraints are intact, with no bypasses; competent service evidence verifies fitted interlocks safely.
□
□
□
067
Operators isolate equipment before clearing jams, changing hazardous parts or cleaning; restart is controlled.
□
□
□
068
Emergency stops and local isolators are clearly identified, accessible and checked through an authorised safe procedure.
□
□
□
069
Oven/proofer doors, racks and controls are safe; uncontrolled heating, smoke or unsafe steam leakage stops use.
□
□
□
070
Dry heat-resistant gloves and stable tray landing areas are available; wet cloths are not used to handle hot trays.
□
□
□
071
Burners, gas connections, hoses and regulators have no visible damage; inspection and replacement dates are tracked.
□
□
□
072
Gas shut-offs are identified and accessible; cylinders and installations meet supplier instructions and applicable local rules.
□
□
□
073
Staff know the gas-leak response and evacuation route; leak checks, repairs and technical work use authorised competent people.
□
□
□
074
Plugs, cords and sockets are sound, dry and protected from heat; damaged electrical equipment is isolated from use.
□
□
□
075
No overloaded adaptors or daisy-chained leads; a competent electrician has checked supply, earthing and protective devices.
□
□
□
076
Fire extinguishers of the locally required type and other required fire equipment are visible, accessible and in service date.
□
□
□
077
Required alarms, exits and emergency lighting work; escape needs no key and the assembly point is identified.
□
□
□
078
Flour dust, grease, paper, packaging and flammables do not accumulate near heat or ignition sources.
□
□
□
079
Knife storage is secure; stable cutting boards, safe carrying practices and suitable tools prevent improvised cutting.
□
□
□
080
Preventive maintenance, breakdowns and repairs are logged; equipment is released back to use only after a safe-function check.
□
□
□
Evidence and readings: __________________________________________________________________
Class readiness teaching and records
ID
Onsite check
P
F
N/A
Ref
081
Class size meets verified occupancy limits, safe station capacity and effective instructor supervision of hazardous tasks.
□
□
□
082
Each class starts with task risks, hygiene, allergens, hot areas, emergency stops, exits and incident-reporting instructions.
□
□
□
083
Students demonstrate safe machine use before independent operation; inexperienced users receive direct supervision.
□
□
□
084
Class rules cover hot-tray calls, clear walkways, one-way movement where needed and safe handover of hot items.
□
□
□
085
Hot sugar, caramel, steam, torches, fryers and sharp-tool tasks have specific controls, safe zones and instructor oversight.
□
□
□
086
Station layout keeps water, electrics, raw ingredients, finished products and waste from interfering with each other.
□
□
□
087
Ingredients are pre-weighed and identified; substitutions and stock shortages are resolved before the demonstration.
□
□
□
088
Enough clean tools, trays, moulds and ingredients are ready; equipment allocation avoids unsafe crowding or rushing.
□
□
□
089
Scales, timers, thermometers and oven settings are checked; recipe weights and process checkpoints are consistently taught.
□
□
□
090
Students understand and can see/hear instructions without unsafe crowding; access and evacuation assistance are planned.
□
□
□
091
Student allergies and support needs are handled confidentially; appropriate task adjustments and emergency arrangements are known.
□
□
□
092
An instructor releases products for tasting or take-home; food cools before wrapping and clean food-grade packaging is used.
□
□
□
093
Current campus approvals, applicable FSSAI licence/registration and responsible-person details are available and match operations.
□
□
□
094
Required handler training, medical-fitness records and food-safety supervision arrangements are current and retrievable.
□
□
□
095
Receiving, temperature, cleaning, pest, water, maintenance and incident records are complete, legible and reviewed for recurring gaps.
□
□
□
096
Previous failures have owners and due dates; repeat defects, near misses, complaints and food withdrawals trigger review and action.
□
□
□
Evidence and readings: __________________________________________________________________
Per class opening
ID
Onsite check
P
F
N/A
Ref
O1
Complete the safety gate; check gas, electrics, guards, fire access and clear escape routes.
□
□
□
O2
Confirm the lead instructor, attendance, safe station capacity and task supervision.
Brief students on today’s hazards, machines, allergens and emergency response.
□
□
□
O8
Confirm recipe limits, timers, probes, cooling space and batch record sheets.
□
□
□
Evidence and readings: __________________________________________________________________
Per class closing
ID
Onsite check
P
F
N/A
Ref
C1
Label, cover and safely store ingredients and products; record relevant final temperatures.
□
□
□
C2
Hold or dispose of unsafe food through the approved process; record significant wastage.
□
□
□
C3
Isolate equipment safely; clean, sanitise and dry machines, worktops and small tools.
□
□
□
C4
Clean sinks, floors and drains; remove waste and check for pest evidence.
□
□
□
C5
Isolate gas and equipment as required; leave essential refrigeration operating.
□
□
□
C6
Secure knives, chemicals and faulty equipment; restock hygiene supplies and tools.
□
□
□
C7
Log incidents, failures and shortages; assign an owner and due date and escalate risks.
□
□
□
C8
Check doors and building handover; sign off only when outstanding risks are controlled.
□
□
□
Evidence and readings: __________________________________________________________________
Corrective action and closure record
Use one record per onsite failure. Record specific location, equipment or product, actual reading, time and evidence. Do not include private student health details.
Verified by and date: _____________________ Recheck date: _____________________
Status: □ Open □ Contained □ Awaiting verification □ Closed
Walkthrough closure
Keep restrictions in place until the appropriate lead verifies that corrections work. A completed work order alone is not closure evidence.
Areas not inspected and N/A reasons: ______________________________________________
Open actions and restrictions: ____________________________________________________
Inspector and date: _____________________ Campus lead and date: _____________________
Next review date: _____________________ Reopening authorised by and time: _____________________
Checklist reference notes
Numerical food-safety limits in this appendix are reproduced from the companion checklist, which cites the FSSAI revised catering criteria dated 3 April 2025. Apply them only to the relevant food and process, confirm the current applicable criteria, and follow tighter supplier instructions or validated product limits. Recipe quality targets such as dough temperature, proofing or chocolate tempering are separate. HSE material is technical good practice, not Indian law; Delhi guidance is not a site approval. The links below support the generic checklist, not a finding that the photographed premises pass or fail a rule.
The 13 photographs are reproduced in upload order, with permanent report references P01 to P13. The notes below retain the supplied wording; recommendations are separately identified above.
Lower-wall corner with multiple electrical outlets beside a stainless steel fixture; exact room not confirmed
Also the image with the corner, it's quite dirty right now and we need to figure out what to place there after cleanup.
What still needs confirmation
Campus, full address, inspection date and exact room for each photo.
Scope of each repair, quantities, measurements, material condition and any concealed defect.
Fan wiring and outlet condition through a qualified person where relevant; the presence and source of any moisture.
Extinguisher type, suitability, readiness, service record and approved location.
Sign wording, compartment contents, current cleaning-log entries and the final use of the corner.
Assigned owners, approved spending, target dates and verification of completed work.
Assessment limits
This is a photo-based maintenance and presentation report. No site visit, measurements, electrical tests, fire-equipment service, food sampling or records audit has been performed for these findings. A photograph cannot establish concealed conditions, total quantities, operating performance or regulatory compliance. Additional issues may exist outside the photographed areas.
The bathroom cleaning log is present in P02; its dates and completeness are not reliably readable. Overloading in P07 is user-reported because contents are not visible. No active leak or mold diagnosis is made from P06 or P13. The chair replacement quantity and structural condition require an onsite check.
The blank checklist is a separate operational aid within this file. Its checks are not additional findings and its boxes do not constitute a site result.